Sub Zero Refrigerator Not Cooling – Refrigerator Restore Assistance

Sub Zero refrigerators have two individual compressors, a single for the freezer along with the other for the refrigerator ball screw repair.

Sub Zero Fridge no great opportunities:

-Dirty/clogged condenser coil
-Defective condenser lover motor
-Defrost thermostat(Located on freezer evaporator)
-Leaking evaporator

Leaking evaporator job’s make up for most of our Sub Zero no cool problems. More than time the evaporator will stop working as well as freon that may be inside of will slowly and gradually leak out. When this happens you might begin to recognize you need to switch the command colder and colder.

Another indicator is that if you recognize frost in the upper remaining hand corner while in the refrigerator. When freon leaks out it is going to produce a frost ball on the capillary tube, consequently producing seen frost within the again panel of your refrigerator. This repair must only be done by an expert licensed CFC technician. To manage freon you need to be licensed.

Sub Zero condenser fan motors will frequently are unsuccessful, when doing this it’s going to generate a no awesome issue. To validate the procedure in the condenser fan motor clear away the grill assembly.

You will find a number of screws coming in within the bottom facet with the in the grill once taken off the grills major will pull ahead and reveal two springs, take out the springs and grill will elevate off. Specific Sub Zero refrigerator’s and freezer’s grill’s are removed by lifting straight up around the panel, the bolt heads slide away from the metallic bracket.

Together with the grill placed safely and securely from how, you will note the lover motor inside the middle up major. The supporter is positioned within the center, this permits the lover to cool each the compressor and the condenser.

The supporter really should be running when ever the compressor is turned on, in case the compressor is operating so should really the enthusiast. In case the comp is running as well as supporter is just not you more than very likely have a very unsuccessful admirer motor.

To validate this use a volt meter and check the 2 wires heading towards the condenser enthusiast motor, there need to be 110v present.

You might find the device is defrost method any time you access by the panel, if this is the situation you could just progress the timer into awesome mode. To take action twist the middle component in the timer having a little screwdriver. The center will twist consequently sending the fridge into great manner. You ought to hear the compressors and fan during the freezer jogging once the device enters cool method, the condenser enthusiast motor ought to even be running.

Leave a Reply